Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating
The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.
Product Picture
Specification
1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-32T-1030-1080 | 32 | 31.79 | 10 | ±7.6° | Φ 8.5 (6 × 6) | 6.2 | 90 | 1.4 | M85 × 1 |
f-65T-1030-1080 | 65 | 80.99 | 10 | ±16° | Φ 36 (26 × 26) | 12.65 | 90 | 0.58 | M85 × 1 |
f-88T-20-1030-1080 | 88 | 120.51 | 20 | ±9.5° | Φ 28.28 (20 × 20) | 8.78 | 120 | 1.3 | M85 × 1 |
f-90T-20-1030-1080 | 90 | 101.323 | 20 | ±17° | Φ 54 (38 × 38) | 35 | 120 | 1.9 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.59 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 135 | 0.59 | M85 × 1 |
f-100T-14-1030-1080 | 100 | 130.44 | 14 | ±20° | Φ 72 (51 × 51) | 13.9 | 120 | 0.5 | M85 × 1 |
f-120T-1030-1080 | 120 | 168.59 | 10 | ±24° | Φ 98 (70 × 70) | 23.5 | 120 | 3 | M85 × 1 |
f-125T-14-1030-1080 | 125 | 153.27 | 14 | ±16.5° | Φ 77.7 (55 × 55) | 17.39 | 112 | 2 | M85 × 1 |
f-125T-20-1030-1080 | 125 | 153.27 | 20 | ±18° | Φ 70.7 (50 × 50) | 12.17 | 112 | 1.8 | M85 × 1 |
f-167T-1030-1080 | 167 | 215.5 | 14 | ±20.3° | Φ 120 (85 × 85) | 17 | 140 | 3.69 | M85 × 1 |
f-200T-14-1030-1080 | 200 | 296.954 | 14 | ±20° | Φ 141 (100×100) | 27.82 | 173 | 2 | M85 × 1 |
f-254T-14-1030-1080 | 254 | 376.53 | 14 | ±18° | Φ155.5(110×110) | 35.3 | 126 | 5 | M85 × 1 |
1064nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-1064 | 100 | 122.8 | 15 | ±22° | Φ 77 (55 × 55) | 13 | 120 | 2.1 | M85 × 1 |
f-125T-1064 | 125 | 139.58 | 20 | ±21.5° | Φ 109 (66 × 66) | 12 | 120 | 3 | M85 × 1 |
f-167T-1064* | 167 | 216.23 | 20 | ±21° | Φ 125 (90 × 90) | 16.5 | 140 | 4.4 | M85 × 1 |
F-170T-30-1064 * | 170 | 209.61 | 30 | ±21° | Φ 120 (88 × 88) | 11.1 | 140 | 4.4 | M102 × 1;M112 |
f-183T-20-1064* | 183 | 219.63 | 20 | ±11.5° | Φ 70.7 (50×50) | 17.82 | 113 | 0.8 | M85 × 1 |
f-210T-30-1064-M95 * | 210 | 279.63 | 30 | ±22° | Φ 161 (115×115) | 13.69 | 188 | 3.3 | M95×1 |
f-210T-30-1064-M102 * | 210 | 279.63 | 30 | ±21° | Φ 154(108×108) | 13.69 | 188 | 3.3 | M102×1 |
f-211T-10-1064-M85 * | 211 | 279.63 | 10 | ±20° | Φ 147(104×104) | 41.1 | 150 | 4.4 | M85 × 1 |
f-315T-14-1064B* | 315 | 432.072 | 14 | ±24.5° | Φ 269(190×190) | 43.8 | 270 | 2.3 | M85 × 1 |
355nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | ||
f-30T-355 | 30 | 35.347 | 10 | ±10.5º | Φ 8.5 (8 x 8) | 1.95 | 47.4 | M39 × 1 |
f-32T-355B | 32 | 26.34 | 10 | ±7.6º | Φ 8.5 (1 x 1) | 3.2 | 90 | M85 × 1 |
f-60T-355 | 60 | 73.65 | 10 | ±16º | Φ 31 (22 × 22) | 11.5 | 90 | M85 × 1 |
f-65T-355 | 65 | 81.106 | 10 | ±9.4º | Φ 21.2 (15 x 15) | 4.2 | 94 | M85 × 1 |
f-70T-355 | 73.9 | 91.35 | 10 | ±16º | Φ 40 (28 x 28) | 4.5 | 90 | M85 × 1 |
f-100T-355 | 100 | 107.68 | 14 | ±20.4 º | Φ71 (50.8 × 50.8) | 6.69 | 120 | M85 × 1 |
f-100T-14-355B | 100 | 135.475 | 14 | ±21º | Φ 70.7 (50 x 50) beam=14mm | 5 | 120 | M85 × 1 |
f-103T-355 | 103 | 136.13 | 12 | ±20.4º | Φ 72 (51 × 51) | 5.58 | 100 | M85 × 1 |
f-110T-355 | 110 | 153.88 | 8 | ±24º | Φ 92 (65 × 65) | 8.9 | 120 | M85 × 1 |
f-120T-355 | 120 | 149.107 | 10 | ±22.5º | Φ 92 (65 × 65) | 8 | 118 | M85 × 1 |
f-130T-355 | 130 | 159.92 | 10 | ±19º | Φ 85 (60 × 60) | 8.45 | 120 | M85 × 1 |
f-167T-10-355 | 167 | 211.25 | 10 | ±24º | Φ 127 (90 × 90) | 10.8 | 130 | M85 × 1 |
f-167T-14-355 | 167 | 234.52 | 14 | ±18º | Φ 99 (70 × 70) | 7.8 | 140 | M85 × 1 |
F-167T-14-355B | 166.57 | 229.163 | 14 | ±22º | Φ 127 (90 × 90) | 7.7 | 159 | M85 × 1 |
f-175T-355 | 175 | 247.487 | 10 | ±24º | Φ 142 (101 × 101) | 11.8 | 140 | M85 × 1 |
f-295T-14-355 | 295 | 426.75 | 14 | ±23.7º | Φ244 (172 x 172) | 13 | 280 | M85 × 1 |
f-330T-355 | 330 | 581.581 | 14 | ±20º | Φ 245 (173 × 173) | 15.3 | 270 | M85 × 1 |
532nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-63T-510-550 | 63 | 82.1 | 10 | ±16° | Φ 33 (23 × 23) | 6.2 | 90 | 1 | M85 × 1 |
f-88T-14-510-550 | 88 | 100.63 | 14 | ±17° | Φ 52 (37 × 37) | 10 | 120 | 1.9 | M85 × 1 |
f-100T-510-550 | 100 | 142.2 | 10 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.38 | M85 × 1 |
f-100T-14-510-550 | 100 | 135.402 | 14 | ±21° | Φ 70.7 (50 × 50) | 7 | 120 | 1.3 | M85 × 1 |
F-167T-14-510-550 | 167 | 232.23 | 14 | ±21° | Φ 127 (90 × 90) | 11.61 | 140 | 3 | M85 × 1 |
532nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-532 | 100 | 125.04 | 15 | ±21.5° | Φ 71 (50 × 50) | 6.5 | 120 | 3.2 | M85 × 1 |
f-110T-532 | 110 | 132.94 | 15 | ±21.5° | Φ 83 (60 × 60) | 7.2 | 120 | 3.2 | M85 × 1 |
f-170T-532 | 170 | 214.66 | 14 | ±21.8° | Φ 129 (91 × 91) | 11.8 | 140 | 3 | M85 × 1 |
f-170T-20-532 | 170 | 204.788 | 20 | ±24° | Φ 141 (100 × 100) | 8.53 | 164 | 4 | M102 × 1 |
Product detail pictures:
Related Product Guide:
All we do is often involved with our tenet Purchaser to start with, Rely on initially, devoting over the food stuff packaging and environmental defense for 2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Swiss, Australia, Afghanistan, We also have the strong ability of integration to supply our best service, and plan to build the warehouse in the different countries around the world, that will be more conveniently to service our customers.
By Athena from Czech republic - 2017.10.13 10:47
As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
By Diana from Norway - 2017.03.28 12:22