2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ
2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ Detail:
Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating
The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.
Product Picture
Specification
1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-32T-1030-1080 | 32 | 31.79 | 10 | ±7.6° | Φ 8.5 (6 × 6) | 6.2 | 90 | 1.4 | M85 × 1 |
f-65T-1030-1080 | 65 | 80.99 | 10 | ±16° | Φ 36 (26 × 26) | 12.65 | 90 | 0.58 | M85 × 1 |
f-88T-20-1030-1080 | 88 | 120.51 | 20 | ±9.5° | Φ 28.28 (20 × 20) | 8.78 | 120 | 1.3 | M85 × 1 |
f-90T-20-1030-1080 | 90 | 101.323 | 20 | ±17° | Φ 54 (38 × 38) | 35 | 120 | 1.9 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.59 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 135 | 0.59 | M85 × 1 |
f-100T-14-1030-1080 | 100 | 130.44 | 14 | ±20° | Φ 72 (51 × 51) | 13.9 | 120 | 0.5 | M85 × 1 |
f-120T-1030-1080 | 120 | 168.59 | 10 | ±24° | Φ 98 (70 × 70) | 23.5 | 120 | 3 | M85 × 1 |
f-125T-14-1030-1080 | 125 | 153.27 | 14 | ±16.5° | Φ 77.7 (55 × 55) | 17.39 | 112 | 2 | M85 × 1 |
f-125T-20-1030-1080 | 125 | 153.27 | 20 | ±18° | Φ 70.7 (50 × 50) | 12.17 | 112 | 1.8 | M85 × 1 |
f-167T-1030-1080 | 167 | 215.5 | 14 | ±20.3° | Φ 120 (85 × 85) | 17 | 140 | 3.69 | M85 × 1 |
f-200T-14-1030-1080 | 200 | 296.954 | 14 | ±20° | Φ 141 (100×100) | 27.82 | 173 | 2 | M85 × 1 |
f-254T-14-1030-1080 | 254 | 376.53 | 14 | ±18° | Φ155.5(110×110) | 35.3 | 126 | 5 | M85 × 1 |
1064nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-1064 | 100 | 122.8 | 15 | ±22° | Φ 77 (55 × 55) | 13 | 120 | 2.1 | M85 × 1 |
f-125T-1064 | 125 | 139.58 | 20 | ±21.5° | Φ 109 (66 × 66) | 12 | 120 | 3 | M85 × 1 |
f-167T-1064* | 167 | 216.23 | 20 | ±21° | Φ 125 (90 × 90) | 16.5 | 140 | 4.4 | M85 × 1 |
F-170T-30-1064 * | 170 | 209.61 | 30 | ±21° | Φ 120 (88 × 88) | 11.1 | 140 | 4.4 | M102 × 1;M112 |
f-183T-20-1064* | 183 | 219.63 | 20 | ±11.5° | Φ 70.7 (50×50) | 17.82 | 113 | 0.8 | M85 × 1 |
f-210T-30-1064-M95 * | 210 | 279.63 | 30 | ±22° | Φ 161 (115×115) | 13.69 | 188 | 3.3 | M95×1 |
f-210T-30-1064-M102 * | 210 | 279.63 | 30 | ±21° | Φ 154(108×108) | 13.69 | 188 | 3.3 | M102×1 |
f-211T-10-1064-M85 * | 211 | 279.63 | 10 | ±20° | Φ 147(104×104) | 41.1 | 150 | 4.4 | M85 × 1 |
f-315T-14-1064B* | 315 | 432.072 | 14 | ±24.5° | Φ 269(190×190) | 43.8 | 270 | 2.3 | M85 × 1 |
355nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | ||
f-30T-355 | 30 | 35.347 | 10 | ±10.5º | Φ 8.5 (8 x 8) | 1.95 | 47.4 | M39 × 1 |
f-32T-355B | 32 | 26.34 | 10 | ±7.6º | Φ 8.5 (1 x 1) | 3.2 | 90 | M85 × 1 |
f-60T-355 | 60 | 73.65 | 10 | ±16º | Φ 31 (22 × 22) | 11.5 | 90 | M85 × 1 |
f-65T-355 | 65 | 81.106 | 10 | ±9.4º | Φ 21.2 (15 x 15) | 4.2 | 94 | M85 × 1 |
f-70T-355 | 73.9 | 91.35 | 10 | ±16º | Φ 40 (28 x 28) | 4.5 | 90 | M85 × 1 |
f-100T-355 | 100 | 107.68 | 14 | ±20.4 º | Φ71 (50.8 × 50.8) | 6.69 | 120 | M85 × 1 |
f-100T-14-355B | 100 | 135.475 | 14 | ±21º | Φ 70.7 (50 x 50) beam=14mm | 5 | 120 | M85 × 1 |
f-103T-355 | 103 | 136.13 | 12 | ±20.4º | Φ 72 (51 × 51) | 5.58 | 100 | M85 × 1 |
f-110T-355 | 110 | 153.88 | 8 | ±24º | Φ 92 (65 × 65) | 8.9 | 120 | M85 × 1 |
f-120T-355 | 120 | 149.107 | 10 | ±22.5º | Φ 92 (65 × 65) | 8 | 118 | M85 × 1 |
f-130T-355 | 130 | 159.92 | 10 | ±19º | Φ 85 (60 × 60) | 8.45 | 120 | M85 × 1 |
f-167T-10-355 | 167 | 211.25 | 10 | ±24º | Φ 127 (90 × 90) | 10.8 | 130 | M85 × 1 |
f-167T-14-355 | 167 | 234.52 | 14 | ±18º | Φ 99 (70 × 70) | 7.8 | 140 | M85 × 1 |
F-167T-14-355B | 166.57 | 229.163 | 14 | ±22º | Φ 127 (90 × 90) | 7.7 | 159 | M85 × 1 |
f-175T-355 | 175 | 247.487 | 10 | ±24º | Φ 142 (101 × 101) | 11.8 | 140 | M85 × 1 |
f-295T-14-355 | 295 | 426.75 | 14 | ±23.7º | Φ244 (172 x 172) | 13 | 280 | M85 × 1 |
f-330T-355 | 330 | 581.581 | 14 | ±20º | Φ 245 (173 × 173) | 15.3 | 270 | M85 × 1 |
532nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-63T-510-550 | 63 | 82.1 | 10 | ±16° | Φ 33 (23 × 23) | 6.2 | 90 | 1 | M85 × 1 |
f-88T-14-510-550 | 88 | 100.63 | 14 | ±17° | Φ 52 (37 × 37) | 10 | 120 | 1.9 | M85 × 1 |
f-100T-510-550 | 100 | 142.2 | 10 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.38 | M85 × 1 |
f-100T-14-510-550 | 100 | 135.402 | 14 | ±21° | Φ 70.7 (50 × 50) | 7 | 120 | 1.3 | M85 × 1 |
F-167T-14-510-550 | 167 | 232.23 | 14 | ±21° | Φ 127 (90 × 90) | 11.61 | 140 | 3 | M85 × 1 |
532nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-532 | 100 | 125.04 | 15 | ±21.5° | Φ 71 (50 × 50) | 6.5 | 120 | 3.2 | M85 × 1 |
f-110T-532 | 110 | 132.94 | 15 | ±21.5° | Φ 83 (60 × 60) | 7.2 | 120 | 3.2 | M85 × 1 |
f-170T-532 | 170 | 214.66 | 14 | ±21.8° | Φ 129 (91 × 91) | 11.8 | 140 | 3 | M85 × 1 |
f-170T-20-532 | 170 | 204.788 | 20 | ±24° | Φ 141 (100 × 100) | 8.53 | 164 | 4 | M102 × 1 |
Product detail pictures:
Related Product Guide:
Our aim is usually to give superior quality items at aggressive rates, and top-notch company to clients around the earth. We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for 2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Detroit, Italy, Dominica, We've been consistently broadening the market within Romania in addition to preparation punching in extra premium quality merchandise connected with printer on t shirt so that you can Romania. Most people firmly believe we've the whole capacity to provide you happy solutions.