2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ
2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ Detail:
Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating
The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.
Product Picture
Specification
1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-32T-1030-1080 | 32 | 31.79 | 10 | ±7.6° | Φ 8.5 (6 × 6) | 6.2 | 90 | 1.4 | M85 × 1 |
f-65T-1030-1080 | 65 | 80.99 | 10 | ±16° | Φ 36 (26 × 26) | 12.65 | 90 | 0.58 | M85 × 1 |
f-88T-20-1030-1080 | 88 | 120.51 | 20 | ±9.5° | Φ 28.28 (20 × 20) | 8.78 | 120 | 1.3 | M85 × 1 |
f-90T-20-1030-1080 | 90 | 101.323 | 20 | ±17° | Φ 54 (38 × 38) | 35 | 120 | 1.9 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.59 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 135 | 0.59 | M85 × 1 |
f-100T-14-1030-1080 | 100 | 130.44 | 14 | ±20° | Φ 72 (51 × 51) | 13.9 | 120 | 0.5 | M85 × 1 |
f-120T-1030-1080 | 120 | 168.59 | 10 | ±24° | Φ 98 (70 × 70) | 23.5 | 120 | 3 | M85 × 1 |
f-125T-14-1030-1080 | 125 | 153.27 | 14 | ±16.5° | Φ 77.7 (55 × 55) | 17.39 | 112 | 2 | M85 × 1 |
f-125T-20-1030-1080 | 125 | 153.27 | 20 | ±18° | Φ 70.7 (50 × 50) | 12.17 | 112 | 1.8 | M85 × 1 |
f-167T-1030-1080 | 167 | 215.5 | 14 | ±20.3° | Φ 120 (85 × 85) | 17 | 140 | 3.69 | M85 × 1 |
f-200T-14-1030-1080 | 200 | 296.954 | 14 | ±20° | Φ 141 (100×100) | 27.82 | 173 | 2 | M85 × 1 |
f-254T-14-1030-1080 | 254 | 376.53 | 14 | ±18° | Φ155.5(110×110) | 35.3 | 126 | 5 | M85 × 1 |
1064nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-1064 | 100 | 122.8 | 15 | ±22° | Φ 77 (55 × 55) | 13 | 120 | 2.1 | M85 × 1 |
f-125T-1064 | 125 | 139.58 | 20 | ±21.5° | Φ 109 (66 × 66) | 12 | 120 | 3 | M85 × 1 |
f-167T-1064* | 167 | 216.23 | 20 | ±21° | Φ 125 (90 × 90) | 16.5 | 140 | 4.4 | M85 × 1 |
F-170T-30-1064 * | 170 | 209.61 | 30 | ±21° | Φ 120 (88 × 88) | 11.1 | 140 | 4.4 | M102 × 1;M112 |
f-183T-20-1064* | 183 | 219.63 | 20 | ±11.5° | Φ 70.7 (50×50) | 17.82 | 113 | 0.8 | M85 × 1 |
f-210T-30-1064-M95 * | 210 | 279.63 | 30 | ±22° | Φ 161 (115×115) | 13.69 | 188 | 3.3 | M95×1 |
f-210T-30-1064-M102 * | 210 | 279.63 | 30 | ±21° | Φ 154(108×108) | 13.69 | 188 | 3.3 | M102×1 |
f-211T-10-1064-M85 * | 211 | 279.63 | 10 | ±20° | Φ 147(104×104) | 41.1 | 150 | 4.4 | M85 × 1 |
f-315T-14-1064B* | 315 | 432.072 | 14 | ±24.5° | Φ 269(190×190) | 43.8 | 270 | 2.3 | M85 × 1 |
355nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | ||
f-30T-355 | 30 | 35.347 | 10 | ±10.5º | Φ 8.5 (8 x 8) | 1.95 | 47.4 | M39 × 1 |
f-32T-355B | 32 | 26.34 | 10 | ±7.6º | Φ 8.5 (1 x 1) | 3.2 | 90 | M85 × 1 |
f-60T-355 | 60 | 73.65 | 10 | ±16º | Φ 31 (22 × 22) | 11.5 | 90 | M85 × 1 |
f-65T-355 | 65 | 81.106 | 10 | ±9.4º | Φ 21.2 (15 x 15) | 4.2 | 94 | M85 × 1 |
f-70T-355 | 73.9 | 91.35 | 10 | ±16º | Φ 40 (28 x 28) | 4.5 | 90 | M85 × 1 |
f-100T-355 | 100 | 107.68 | 14 | ±20.4 º | Φ71 (50.8 × 50.8) | 6.69 | 120 | M85 × 1 |
f-100T-14-355B | 100 | 135.475 | 14 | ±21º | Φ 70.7 (50 x 50) beam=14mm | 5 | 120 | M85 × 1 |
f-103T-355 | 103 | 136.13 | 12 | ±20.4º | Φ 72 (51 × 51) | 5.58 | 100 | M85 × 1 |
f-110T-355 | 110 | 153.88 | 8 | ±24º | Φ 92 (65 × 65) | 8.9 | 120 | M85 × 1 |
f-120T-355 | 120 | 149.107 | 10 | ±22.5º | Φ 92 (65 × 65) | 8 | 118 | M85 × 1 |
f-130T-355 | 130 | 159.92 | 10 | ±19º | Φ 85 (60 × 60) | 8.45 | 120 | M85 × 1 |
f-167T-10-355 | 167 | 211.25 | 10 | ±24º | Φ 127 (90 × 90) | 10.8 | 130 | M85 × 1 |
f-167T-14-355 | 167 | 234.52 | 14 | ±18º | Φ 99 (70 × 70) | 7.8 | 140 | M85 × 1 |
F-167T-14-355B | 166.57 | 229.163 | 14 | ±22º | Φ 127 (90 × 90) | 7.7 | 159 | M85 × 1 |
f-175T-355 | 175 | 247.487 | 10 | ±24º | Φ 142 (101 × 101) | 11.8 | 140 | M85 × 1 |
f-295T-14-355 | 295 | 426.75 | 14 | ±23.7º | Φ244 (172 x 172) | 13 | 280 | M85 × 1 |
f-330T-355 | 330 | 581.581 | 14 | ±20º | Φ 245 (173 × 173) | 15.3 | 270 | M85 × 1 |
532nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-63T-510-550 | 63 | 82.1 | 10 | ±16° | Φ 33 (23 × 23) | 6.2 | 90 | 1 | M85 × 1 |
f-88T-14-510-550 | 88 | 100.63 | 14 | ±17° | Φ 52 (37 × 37) | 10 | 120 | 1.9 | M85 × 1 |
f-100T-510-550 | 100 | 142.2 | 10 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.38 | M85 × 1 |
f-100T-14-510-550 | 100 | 135.402 | 14 | ±21° | Φ 70.7 (50 × 50) | 7 | 120 | 1.3 | M85 × 1 |
F-167T-14-510-550 | 167 | 232.23 | 14 | ±21° | Φ 127 (90 × 90) | 11.61 | 140 | 3 | M85 × 1 |
532nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-532 | 100 | 125.04 | 15 | ±21.5° | Φ 71 (50 × 50) | 6.5 | 120 | 3.2 | M85 × 1 |
f-110T-532 | 110 | 132.94 | 15 | ±21.5° | Φ 83 (60 × 60) | 7.2 | 120 | 3.2 | M85 × 1 |
f-170T-532 | 170 | 214.66 | 14 | ±21.8° | Φ 129 (91 × 91) | 11.8 | 140 | 3 | M85 × 1 |
f-170T-20-532 | 170 | 204.788 | 20 | ±24° | Φ 141 (100 × 100) | 8.53 | 164 | 4 | M102 × 1 |
Product detail pictures:
Related Product Guide:
We generally believe that one's character decides products' top quality, the details decides products' high-quality ,along with the REALISTIC,EFFICIENT AND INNOVATIVE team spirit for 2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Seychelles, Egypt, Oman, Ensuring high product quality by choosing the best suppliers, we have also implemented comprehensive quality control processes throughout our sourcing procedures. Meanwhile, our access to a large range of factories, coupled with our excellent management, also ensures that we can quickly fill your requirements at the best prices, regardless the order size.
By Pearl Permewan from Detroit - 2017.08.28 16:02
This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
By Mona from Luxembourg - 2017.12.09 14:01