2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ
2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ Detail:
Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating
The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.
Product Picture
Specification
1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-32T-1030-1080 | 32 | 31.79 | 10 | ±7.6° | Φ 8.5 (6 × 6) | 6.2 | 90 | 1.4 | M85 × 1 |
f-65T-1030-1080 | 65 | 80.99 | 10 | ±16° | Φ 36 (26 × 26) | 12.65 | 90 | 0.58 | M85 × 1 |
f-88T-20-1030-1080 | 88 | 120.51 | 20 | ±9.5° | Φ 28.28 (20 × 20) | 8.78 | 120 | 1.3 | M85 × 1 |
f-90T-20-1030-1080 | 90 | 101.323 | 20 | ±17° | Φ 54 (38 × 38) | 35 | 120 | 1.9 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.59 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 135 | 0.59 | M85 × 1 |
f-100T-14-1030-1080 | 100 | 130.44 | 14 | ±20° | Φ 72 (51 × 51) | 13.9 | 120 | 0.5 | M85 × 1 |
f-120T-1030-1080 | 120 | 168.59 | 10 | ±24° | Φ 98 (70 × 70) | 23.5 | 120 | 3 | M85 × 1 |
f-125T-14-1030-1080 | 125 | 153.27 | 14 | ±16.5° | Φ 77.7 (55 × 55) | 17.39 | 112 | 2 | M85 × 1 |
f-125T-20-1030-1080 | 125 | 153.27 | 20 | ±18° | Φ 70.7 (50 × 50) | 12.17 | 112 | 1.8 | M85 × 1 |
f-167T-1030-1080 | 167 | 215.5 | 14 | ±20.3° | Φ 120 (85 × 85) | 17 | 140 | 3.69 | M85 × 1 |
f-200T-14-1030-1080 | 200 | 296.954 | 14 | ±20° | Φ 141 (100×100) | 27.82 | 173 | 2 | M85 × 1 |
f-254T-14-1030-1080 | 254 | 376.53 | 14 | ±18° | Φ155.5(110×110) | 35.3 | 126 | 5 | M85 × 1 |
1064nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-1064 | 100 | 122.8 | 15 | ±22° | Φ 77 (55 × 55) | 13 | 120 | 2.1 | M85 × 1 |
f-125T-1064 | 125 | 139.58 | 20 | ±21.5° | Φ 109 (66 × 66) | 12 | 120 | 3 | M85 × 1 |
f-167T-1064* | 167 | 216.23 | 20 | ±21° | Φ 125 (90 × 90) | 16.5 | 140 | 4.4 | M85 × 1 |
F-170T-30-1064 * | 170 | 209.61 | 30 | ±21° | Φ 120 (88 × 88) | 11.1 | 140 | 4.4 | M102 × 1;M112 |
f-183T-20-1064* | 183 | 219.63 | 20 | ±11.5° | Φ 70.7 (50×50) | 17.82 | 113 | 0.8 | M85 × 1 |
f-210T-30-1064-M95 * | 210 | 279.63 | 30 | ±22° | Φ 161 (115×115) | 13.69 | 188 | 3.3 | M95×1 |
f-210T-30-1064-M102 * | 210 | 279.63 | 30 | ±21° | Φ 154(108×108) | 13.69 | 188 | 3.3 | M102×1 |
f-211T-10-1064-M85 * | 211 | 279.63 | 10 | ±20° | Φ 147(104×104) | 41.1 | 150 | 4.4 | M85 × 1 |
f-315T-14-1064B* | 315 | 432.072 | 14 | ±24.5° | Φ 269(190×190) | 43.8 | 270 | 2.3 | M85 × 1 |
355nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | ||
f-30T-355 | 30 | 35.347 | 10 | ±10.5º | Φ 8.5 (8 x 8) | 1.95 | 47.4 | M39 × 1 |
f-32T-355B | 32 | 26.34 | 10 | ±7.6º | Φ 8.5 (1 x 1) | 3.2 | 90 | M85 × 1 |
f-60T-355 | 60 | 73.65 | 10 | ±16º | Φ 31 (22 × 22) | 11.5 | 90 | M85 × 1 |
f-65T-355 | 65 | 81.106 | 10 | ±9.4º | Φ 21.2 (15 x 15) | 4.2 | 94 | M85 × 1 |
f-70T-355 | 73.9 | 91.35 | 10 | ±16º | Φ 40 (28 x 28) | 4.5 | 90 | M85 × 1 |
f-100T-355 | 100 | 107.68 | 14 | ±20.4 º | Φ71 (50.8 × 50.8) | 6.69 | 120 | M85 × 1 |
f-100T-14-355B | 100 | 135.475 | 14 | ±21º | Φ 70.7 (50 x 50) beam=14mm | 5 | 120 | M85 × 1 |
f-103T-355 | 103 | 136.13 | 12 | ±20.4º | Φ 72 (51 × 51) | 5.58 | 100 | M85 × 1 |
f-110T-355 | 110 | 153.88 | 8 | ±24º | Φ 92 (65 × 65) | 8.9 | 120 | M85 × 1 |
f-120T-355 | 120 | 149.107 | 10 | ±22.5º | Φ 92 (65 × 65) | 8 | 118 | M85 × 1 |
f-130T-355 | 130 | 159.92 | 10 | ±19º | Φ 85 (60 × 60) | 8.45 | 120 | M85 × 1 |
f-167T-10-355 | 167 | 211.25 | 10 | ±24º | Φ 127 (90 × 90) | 10.8 | 130 | M85 × 1 |
f-167T-14-355 | 167 | 234.52 | 14 | ±18º | Φ 99 (70 × 70) | 7.8 | 140 | M85 × 1 |
F-167T-14-355B | 166.57 | 229.163 | 14 | ±22º | Φ 127 (90 × 90) | 7.7 | 159 | M85 × 1 |
f-175T-355 | 175 | 247.487 | 10 | ±24º | Φ 142 (101 × 101) | 11.8 | 140 | M85 × 1 |
f-295T-14-355 | 295 | 426.75 | 14 | ±23.7º | Φ244 (172 x 172) | 13 | 280 | M85 × 1 |
f-330T-355 | 330 | 581.581 | 14 | ±20º | Φ 245 (173 × 173) | 15.3 | 270 | M85 × 1 |
532nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-63T-510-550 | 63 | 82.1 | 10 | ±16° | Φ 33 (23 × 23) | 6.2 | 90 | 1 | M85 × 1 |
f-88T-14-510-550 | 88 | 100.63 | 14 | ±17° | Φ 52 (37 × 37) | 10 | 120 | 1.9 | M85 × 1 |
f-100T-510-550 | 100 | 142.2 | 10 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.38 | M85 × 1 |
f-100T-14-510-550 | 100 | 135.402 | 14 | ±21° | Φ 70.7 (50 × 50) | 7 | 120 | 1.3 | M85 × 1 |
F-167T-14-510-550 | 167 | 232.23 | 14 | ±21° | Φ 127 (90 × 90) | 11.61 | 140 | 3 | M85 × 1 |
532nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-532 | 100 | 125.04 | 15 | ±21.5° | Φ 71 (50 × 50) | 6.5 | 120 | 3.2 | M85 × 1 |
f-110T-532 | 110 | 132.94 | 15 | ±21.5° | Φ 83 (60 × 60) | 7.2 | 120 | 3.2 | M85 × 1 |
f-170T-532 | 170 | 214.66 | 14 | ±21.8° | Φ 129 (91 × 91) | 11.8 | 140 | 3 | M85 × 1 |
f-170T-20-532 | 170 | 204.788 | 20 | ±24° | Φ 141 (100 × 100) | 8.53 | 164 | 4 | M102 × 1 |
Product detail pictures:
Related Product Guide:
We purpose to understand high quality disfigurement with the output and supply the top service to domestic and overseas buyers wholeheartedly for 2018 China New Design Optical Laser Level - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Hungary, Swansea, Luxemburg, We are very responsible for all details on our customers order no matter on warranty quality, satisfied prices, quick delivery, on time communication, satisfied packing, easy payment terms, best shipment terms, after sales service etc. We provide one-stop service and best reliability to our every customers. We work hard with our customers, colleagues, workers to make a better future.
By Christine from Marseille - 2017.03.07 13:42
In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
By Ivy from Senegal - 2018.05.13 17:00