China Cheap price Laser Beam Expander - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ
China Cheap price Laser Beam Expander - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ Detail:
Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating
The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.
Product Picture
Specification
1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-32T-1030-1080 | 32 | 31.79 | 10 | ±7.6° | Φ 8.5 (6 × 6) | 6.2 | 90 | 1.4 | M85 × 1 |
f-65T-1030-1080 | 65 | 80.99 | 10 | ±16° | Φ 36 (26 × 26) | 12.65 | 90 | 0.58 | M85 × 1 |
f-88T-20-1030-1080 | 88 | 120.51 | 20 | ±9.5° | Φ 28.28 (20 × 20) | 8.78 | 120 | 1.3 | M85 × 1 |
f-90T-20-1030-1080 | 90 | 101.323 | 20 | ±17° | Φ 54 (38 × 38) | 35 | 120 | 1.9 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.59 | M85 × 1 |
f-100T-1030-1080 | 100 | 142.73 | 14 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 135 | 0.59 | M85 × 1 |
f-100T-14-1030-1080 | 100 | 130.44 | 14 | ±20° | Φ 72 (51 × 51) | 13.9 | 120 | 0.5 | M85 × 1 |
f-120T-1030-1080 | 120 | 168.59 | 10 | ±24° | Φ 98 (70 × 70) | 23.5 | 120 | 3 | M85 × 1 |
f-125T-14-1030-1080 | 125 | 153.27 | 14 | ±16.5° | Φ 77.7 (55 × 55) | 17.39 | 112 | 2 | M85 × 1 |
f-125T-20-1030-1080 | 125 | 153.27 | 20 | ±18° | Φ 70.7 (50 × 50) | 12.17 | 112 | 1.8 | M85 × 1 |
f-167T-1030-1080 | 167 | 215.5 | 14 | ±20.3° | Φ 120 (85 × 85) | 17 | 140 | 3.69 | M85 × 1 |
f-200T-14-1030-1080 | 200 | 296.954 | 14 | ±20° | Φ 141 (100×100) | 27.82 | 173 | 2 | M85 × 1 |
f-254T-14-1030-1080 | 254 | 376.53 | 14 | ±18° | Φ155.5(110×110) | 35.3 | 126 | 5 | M85 × 1 |
1064nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-1064 | 100 | 122.8 | 15 | ±22° | Φ 77 (55 × 55) | 13 | 120 | 2.1 | M85 × 1 |
f-125T-1064 | 125 | 139.58 | 20 | ±21.5° | Φ 109 (66 × 66) | 12 | 120 | 3 | M85 × 1 |
f-167T-1064* | 167 | 216.23 | 20 | ±21° | Φ 125 (90 × 90) | 16.5 | 140 | 4.4 | M85 × 1 |
F-170T-30-1064 * | 170 | 209.61 | 30 | ±21° | Φ 120 (88 × 88) | 11.1 | 140 | 4.4 | M102 × 1;M112 |
f-183T-20-1064* | 183 | 219.63 | 20 | ±11.5° | Φ 70.7 (50×50) | 17.82 | 113 | 0.8 | M85 × 1 |
f-210T-30-1064-M95 * | 210 | 279.63 | 30 | ±22° | Φ 161 (115×115) | 13.69 | 188 | 3.3 | M95×1 |
f-210T-30-1064-M102 * | 210 | 279.63 | 30 | ±21° | Φ 154(108×108) | 13.69 | 188 | 3.3 | M102×1 |
f-211T-10-1064-M85 * | 211 | 279.63 | 10 | ±20° | Φ 147(104×104) | 41.1 | 150 | 4.4 | M85 × 1 |
f-315T-14-1064B* | 315 | 432.072 | 14 | ±24.5° | Φ 269(190×190) | 43.8 | 270 | 2.3 | M85 × 1 |
355nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | ||
f-30T-355 | 30 | 35.347 | 10 | ±10.5º | Φ 8.5 (8 x 8) | 1.95 | 47.4 | M39 × 1 |
f-32T-355B | 32 | 26.34 | 10 | ±7.6º | Φ 8.5 (1 x 1) | 3.2 | 90 | M85 × 1 |
f-60T-355 | 60 | 73.65 | 10 | ±16º | Φ 31 (22 × 22) | 11.5 | 90 | M85 × 1 |
f-65T-355 | 65 | 81.106 | 10 | ±9.4º | Φ 21.2 (15 x 15) | 4.2 | 94 | M85 × 1 |
f-70T-355 | 73.9 | 91.35 | 10 | ±16º | Φ 40 (28 x 28) | 4.5 | 90 | M85 × 1 |
f-100T-355 | 100 | 107.68 | 14 | ±20.4 º | Φ71 (50.8 × 50.8) | 6.69 | 120 | M85 × 1 |
f-100T-14-355B | 100 | 135.475 | 14 | ±21º | Φ 70.7 (50 x 50) beam=14mm | 5 | 120 | M85 × 1 |
f-103T-355 | 103 | 136.13 | 12 | ±20.4º | Φ 72 (51 × 51) | 5.58 | 100 | M85 × 1 |
f-110T-355 | 110 | 153.88 | 8 | ±24º | Φ 92 (65 × 65) | 8.9 | 120 | M85 × 1 |
f-120T-355 | 120 | 149.107 | 10 | ±22.5º | Φ 92 (65 × 65) | 8 | 118 | M85 × 1 |
f-130T-355 | 130 | 159.92 | 10 | ±19º | Φ 85 (60 × 60) | 8.45 | 120 | M85 × 1 |
f-167T-10-355 | 167 | 211.25 | 10 | ±24º | Φ 127 (90 × 90) | 10.8 | 130 | M85 × 1 |
f-167T-14-355 | 167 | 234.52 | 14 | ±18º | Φ 99 (70 × 70) | 7.8 | 140 | M85 × 1 |
F-167T-14-355B | 166.57 | 229.163 | 14 | ±22º | Φ 127 (90 × 90) | 7.7 | 159 | M85 × 1 |
f-175T-355 | 175 | 247.487 | 10 | ±24º | Φ 142 (101 × 101) | 11.8 | 140 | M85 × 1 |
f-295T-14-355 | 295 | 426.75 | 14 | ±23.7º | Φ244 (172 x 172) | 13 | 280 | M85 × 1 |
f-330T-355 | 330 | 581.581 | 14 | ±20º | Φ 245 (173 × 173) | 15.3 | 270 | M85 × 1 |
532nm Fuced Silica
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | Φ Outside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-63T-510-550 | 63 | 82.1 | 10 | ±16° | Φ 33 (23 × 23) | 6.2 | 90 | 1 | M85 × 1 |
f-88T-14-510-550 | 88 | 100.63 | 14 | ±17° | Φ 52 (37 × 37) | 10 | 120 | 1.9 | M85 × 1 |
f-100T-510-550 | 100 | 142.2 | 10 | ±20.7° | Φ 76 (54 × 54) | 13.5 | 120 | 0.38 | M85 × 1 |
f-100T-14-510-550 | 100 | 135.402 | 14 | ±21° | Φ 70.7 (50 × 50) | 7 | 120 | 1.3 | M85 × 1 |
F-167T-14-510-550 | 167 | 232.23 | 14 | ±21° | Φ 127 (90 × 90) | 11.61 | 140 | 3 | M85 × 1 |
532nm Optical Glass
Part Number | EFL | WD | Φ in | Scan Angle | Scan Field | Spot Size | ΦOutside | Max. IA | Mount Thread |
(mm) | (mm) | (mm) | (mm) | (mm) | (µm) | (mm) | (°) | ||
f-100T-532 | 100 | 125.04 | 15 | ±21.5° | Φ 71 (50 × 50) | 6.5 | 120 | 3.2 | M85 × 1 |
f-110T-532 | 110 | 132.94 | 15 | ±21.5° | Φ 83 (60 × 60) | 7.2 | 120 | 3.2 | M85 × 1 |
f-170T-532 | 170 | 214.66 | 14 | ±21.8° | Φ 129 (91 × 91) | 11.8 | 140 | 3 | M85 × 1 |
f-170T-20-532 | 170 | 204.788 | 20 | ±24° | Φ 141 (100 × 100) | 8.53 | 164 | 4 | M102 × 1 |
Product detail pictures:
Related Product Guide:
Our commission should be to provide our customers and consumers with ideal top quality and aggressive portable digital products for China Cheap price Laser Beam Expander - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Rio de Janeiro, Cambodia, Austria, Our company has already have pass the ISO standard and we are fully respect our customer 's patents and copyrights. If the customer provides their own designs, We will guarantee that they will be the only one can have that products. We hoping that with our good products can bring our customers a great fortune.
By Nicci Hackner from Lithuania - 2018.10.09 19:07
We have been looking for a professional and responsible supplier, and now we find it.
By Judith from Belize - 2017.11.12 12:31