• Laser Marking Control Software
  • Laser Controller
  • Laser Galvo Scanner Head
  • Fiber/UV/CO2 /Green/Picosecond/Femtosecond Laser
  • Laser Optics
  • OEM/OEM Laser Machines | Marking | Welding | Cutting | Cleaning | Trimming

Chinese wholesale Laser Scanning System - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also supply merchandise sourcing and flight consolidation companies. We now have our very own manufacturing facility and sourcing business. We could present you with almost every kind of product relevant to our solution array for Laser Works Software, Laser Software for Marking | Cutting | Welding | Cleaning, Ezcad Laser, We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
Chinese wholesale Laser Scanning System - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ Detail:

Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating

The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.

Product Picture

Standard F-theta Lens-Optical Glass-3
F-theta Scan Lens China Manufacturer 10600nm
Standard F-theta Lens-Optical Glass

Specification

1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-32T-1030-1080 32 31.79 10 ±7.6° Φ 8.5   (6 × 6) 6.2 90 1.4 M85 × 1
f-65T-1030-1080 65 80.99 10 ±16° Φ 36   (26 × 26) 12.65 90 0.58 M85 × 1
f-88T-20-1030-1080 88 120.51 20 ±9.5° Φ 28.28   (20 × 20) 8.78 120 1.3 M85 × 1
f-90T-20-1030-1080 90 101.323 20 ±17° Φ 54   (38 × 38) 35 120 1.9 M85 × 1
f-100T-1030-1080 100 142.73 14 ±20.7° Φ 76   (54 × 54) 13.5 120 0.59 M85 × 1
f-100T-1030-1080 100 142.73 14 ±20.7° Φ 76   (54 × 54) 13.5 135 0.59 M85 × 1
f-100T-14-1030-1080 100 130.44 14 ±20° Φ 72   (51 × 51) 13.9 120 0.5 M85 × 1
f-120T-1030-1080 120 168.59 10 ±24° Φ 98   (70 × 70) 23.5 120 3 M85 × 1
f-125T-14-1030-1080 125 153.27 14 ±16.5° Φ 77.7   (55 × 55) 17.39 112 2 M85 × 1
f-125T-20-1030-1080 125 153.27 20 ±18° Φ 70.7  (50 × 50) 12.17 112 1.8 M85 × 1
f-167T-1030-1080 167 215.5 14 ±20.3° Φ 120  (85 × 85) 17 140 3.69 M85 × 1
f-200T-14-1030-1080 200 296.954 14 ±20° Φ 141 (100×100) 27.82 173 2 M85 × 1
f-254T-14-1030-1080 254 376.53 14 ±18° Φ155.5(110×110) 35.3 126 5 M85 × 1

1064nm Optical Glass

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-100T-1064 100 122.8 15 ±22° Φ 77   (55 × 55) 13 120 2.1 M85 × 1
f-125T-1064 125 139.58 20 ±21.5° Φ 109  (66 × 66) 12 120 3 M85 × 1
f-167T-1064* 167 216.23 20 ±21° Φ 125  (90 × 90) 16.5 140 4.4 M85 × 1
F-170T-30-1064 * 170 209.61 30 ±21° Φ 120  (88 × 88) 11.1 140 4.4 M102 × 1;M112
f-183T-20-1064* 183 219.63 20 ±11.5° Φ 70.7  (50×50) 17.82 113 0.8 M85 × 1
f-210T-30-1064-M95 * 210 279.63 30 ±22° Φ 161 (115×115) 13.69 188 3.3 M95×1
f-210T-30-1064-M102 * 210 279.63 30 ±21° Φ 154(108×108) 13.69 188 3.3 M102×1
f-211T-10-1064-M85 * 211 279.63 10 ±20° Φ 147(104×104) 41.1 150 4.4 M85 × 1
f-315T-14-1064B* 315 432.072 14 ±24.5° Φ 269(190×190) 43.8 270 2.3 M85 × 1

355nm Fuced Silica

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size Φ Outside Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm)
f-30T-355 30 35.347 10 ±10.5º Φ 8.5   (8 x 8) 1.95 47.4 M39 × 1
f-32T-355B 32 26.34 10 ±7.6º Φ 8.5   (1 x 1) 3.2 90 M85 × 1
f-60T-355 60 73.65 10 ±16º Φ 31   (22 × 22) 11.5 90 M85 × 1
f-65T-355 65 81.106 10 ±9.4º Φ 21.2  (15 x 15) 4.2 94 M85 × 1
f-70T-355 73.9 91.35 10 ±16º Φ 40   (28 x 28) 4.5 90 M85 × 1
f-100T-355 100 107.68 14 ±20.4 º Φ71    (50.8 × 50.8) 6.69 120 M85 × 1
f-100T-14-355B 100 135.475 14 ±21º Φ 70.7  (50 x 50) beam=14mm 5 120 M85 × 1
f-103T-355 103 136.13 12 ±20.4º Φ 72   (51 × 51) 5.58 100 M85 × 1
f-110T-355 110 153.88 8 ±24º Φ 92   (65 × 65) 8.9 120 M85 × 1
f-120T-355 120 149.107 10 ±22.5º Φ 92   (65 × 65) 8 118 M85 × 1
f-130T-355 130 159.92 10 ±19º Φ 85   (60 × 60) 8.45 120 M85 × 1
f-167T-10-355 167 211.25 10 ±24º Φ 127  (90 × 90) 10.8 130 M85 × 1
f-167T-14-355 167 234.52 14 ±18º Φ 99   (70 × 70) 7.8 140 M85 × 1
F-167T-14-355B 166.57 229.163 14 ±22º Φ 127  (90 × 90) 7.7 159 M85 × 1
f-175T-355 175 247.487 10 ±24º Φ 142  (101 × 101) 11.8 140 M85 × 1
f-295T-14-355 295 426.75 14 ±23.7º Φ244   (172 x 172) 13 280 M85 × 1
f-330T-355 330 581.581 14 ±20º Φ 245  (173 × 173) 15.3 270 M85 × 1

532nm Fuced Silica

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size Φ Outside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-63T-510-550 63 82.1 10 ±16° Φ 33   (23 × 23) 6.2 90 1 M85 × 1
f-88T-14-510-550 88 100.63 14 ±17° Φ 52   (37 × 37) 10 120 1.9 M85 × 1
f-100T-510-550 100 142.2 10 ±20.7° Φ 76   (54 × 54) 13.5 120 0.38 M85 × 1
f-100T-14-510-550 100 135.402 14 ±21° Φ 70.7  (50 × 50) 7 120 1.3 M85 × 1
F-167T-14-510-550 167 232.23 14 ±21° Φ 127  (90 × 90) 11.61 140 3 M85 × 1

532nm Optical Glass

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-100T-532 100 125.04 15 ±21.5° Φ 71   (50 × 50) 6.5 120 3.2 M85 × 1
f-110T-532 110 132.94 15 ±21.5° Φ 83   (60 × 60) 7.2 120 3.2 M85 × 1
f-170T-532 170 214.66 14 ±21.8° Φ 129  (91 × 91) 11.8 140 3 M85 × 1
f-170T-20-532 170 204.788 20 ±24° Φ 141 (100 × 100) 8.53 164 4 M102 × 1

Product detail pictures:

Chinese wholesale Laser Scanning System - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ detail pictures

Chinese wholesale Laser Scanning System - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ detail pictures

Chinese wholesale Laser Scanning System - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ detail pictures


Related Product Guide:

We have now sophisticated machines. Our solutions are exported to the USA, the UK and so on, enjoying a great reputation amid consumers for Chinese wholesale Laser Scanning System - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Moscow, Frankfurt, Eindhoven, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that customer first and committed to helping customers expand their business, so that they become the Big Boss !
  • The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Roxanne from Latvia - 2017.06.19 13:51
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Erica from Nepal - 2018.12.11 14:13