• Laser Marking Control Software
  • Laser Controller
  • Laser Galvo Scanner Head
  • Fiber/UV/CO2 /Green/Picosecond/Femtosecond Laser
  • Laser Optics
  • OEM/OEM Laser Machines | Marking | Welding | Cutting | Cleaning | Trimming

Wholesale Price China Laser Diode Focusing Lens - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With this motto in mind, we have become one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for Fiber Laser Control Board, Laser Engraver Control Software, Beam Detector, We maintain timely delivery schedules, innovative designs, quality and transparency for our customers. Our moto is to deliver quality products within stipulated time.
Wholesale Price China Laser Diode Focusing Lens - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ Detail:

Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating

The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.

Product Picture

Standard F-theta Lens-Optical Glass-3
F-theta Scan Lens China Manufacturer 10600nm
Standard F-theta Lens-Optical Glass

Specification

1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-32T-1030-1080 32 31.79 10 ±7.6° Φ 8.5   (6 × 6) 6.2 90 1.4 M85 × 1
f-65T-1030-1080 65 80.99 10 ±16° Φ 36   (26 × 26) 12.65 90 0.58 M85 × 1
f-88T-20-1030-1080 88 120.51 20 ±9.5° Φ 28.28   (20 × 20) 8.78 120 1.3 M85 × 1
f-90T-20-1030-1080 90 101.323 20 ±17° Φ 54   (38 × 38) 35 120 1.9 M85 × 1
f-100T-1030-1080 100 142.73 14 ±20.7° Φ 76   (54 × 54) 13.5 120 0.59 M85 × 1
f-100T-1030-1080 100 142.73 14 ±20.7° Φ 76   (54 × 54) 13.5 135 0.59 M85 × 1
f-100T-14-1030-1080 100 130.44 14 ±20° Φ 72   (51 × 51) 13.9 120 0.5 M85 × 1
f-120T-1030-1080 120 168.59 10 ±24° Φ 98   (70 × 70) 23.5 120 3 M85 × 1
f-125T-14-1030-1080 125 153.27 14 ±16.5° Φ 77.7   (55 × 55) 17.39 112 2 M85 × 1
f-125T-20-1030-1080 125 153.27 20 ±18° Φ 70.7  (50 × 50) 12.17 112 1.8 M85 × 1
f-167T-1030-1080 167 215.5 14 ±20.3° Φ 120  (85 × 85) 17 140 3.69 M85 × 1
f-200T-14-1030-1080 200 296.954 14 ±20° Φ 141 (100×100) 27.82 173 2 M85 × 1
f-254T-14-1030-1080 254 376.53 14 ±18° Φ155.5(110×110) 35.3 126 5 M85 × 1

1064nm Optical Glass

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-100T-1064 100 122.8 15 ±22° Φ 77   (55 × 55) 13 120 2.1 M85 × 1
f-125T-1064 125 139.58 20 ±21.5° Φ 109  (66 × 66) 12 120 3 M85 × 1
f-167T-1064* 167 216.23 20 ±21° Φ 125  (90 × 90) 16.5 140 4.4 M85 × 1
F-170T-30-1064 * 170 209.61 30 ±21° Φ 120  (88 × 88) 11.1 140 4.4 M102 × 1;M112
f-183T-20-1064* 183 219.63 20 ±11.5° Φ 70.7  (50×50) 17.82 113 0.8 M85 × 1
f-210T-30-1064-M95 * 210 279.63 30 ±22° Φ 161 (115×115) 13.69 188 3.3 M95×1
f-210T-30-1064-M102 * 210 279.63 30 ±21° Φ 154(108×108) 13.69 188 3.3 M102×1
f-211T-10-1064-M85 * 211 279.63 10 ±20° Φ 147(104×104) 41.1 150 4.4 M85 × 1
f-315T-14-1064B* 315 432.072 14 ±24.5° Φ 269(190×190) 43.8 270 2.3 M85 × 1

355nm Fuced Silica

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size Φ Outside Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm)
f-30T-355 30 35.347 10 ±10.5º Φ 8.5   (8 x 8) 1.95 47.4 M39 × 1
f-32T-355B 32 26.34 10 ±7.6º Φ 8.5   (1 x 1) 3.2 90 M85 × 1
f-60T-355 60 73.65 10 ±16º Φ 31   (22 × 22) 11.5 90 M85 × 1
f-65T-355 65 81.106 10 ±9.4º Φ 21.2  (15 x 15) 4.2 94 M85 × 1
f-70T-355 73.9 91.35 10 ±16º Φ 40   (28 x 28) 4.5 90 M85 × 1
f-100T-355 100 107.68 14 ±20.4 º Φ71    (50.8 × 50.8) 6.69 120 M85 × 1
f-100T-14-355B 100 135.475 14 ±21º Φ 70.7  (50 x 50) beam=14mm 5 120 M85 × 1
f-103T-355 103 136.13 12 ±20.4º Φ 72   (51 × 51) 5.58 100 M85 × 1
f-110T-355 110 153.88 8 ±24º Φ 92   (65 × 65) 8.9 120 M85 × 1
f-120T-355 120 149.107 10 ±22.5º Φ 92   (65 × 65) 8 118 M85 × 1
f-130T-355 130 159.92 10 ±19º Φ 85   (60 × 60) 8.45 120 M85 × 1
f-167T-10-355 167 211.25 10 ±24º Φ 127  (90 × 90) 10.8 130 M85 × 1
f-167T-14-355 167 234.52 14 ±18º Φ 99   (70 × 70) 7.8 140 M85 × 1
F-167T-14-355B 166.57 229.163 14 ±22º Φ 127  (90 × 90) 7.7 159 M85 × 1
f-175T-355 175 247.487 10 ±24º Φ 142  (101 × 101) 11.8 140 M85 × 1
f-295T-14-355 295 426.75 14 ±23.7º Φ244   (172 x 172) 13 280 M85 × 1
f-330T-355 330 581.581 14 ±20º Φ 245  (173 × 173) 15.3 270 M85 × 1

532nm Fuced Silica

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size Φ Outside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-63T-510-550 63 82.1 10 ±16° Φ 33   (23 × 23) 6.2 90 1 M85 × 1
f-88T-14-510-550 88 100.63 14 ±17° Φ 52   (37 × 37) 10 120 1.9 M85 × 1
f-100T-510-550 100 142.2 10 ±20.7° Φ 76   (54 × 54) 13.5 120 0.38 M85 × 1
f-100T-14-510-550 100 135.402 14 ±21° Φ 70.7  (50 × 50) 7 120 1.3 M85 × 1
F-167T-14-510-550 167 232.23 14 ±21° Φ 127  (90 × 90) 11.61 140 3 M85 × 1

532nm Optical Glass

Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-100T-532 100 125.04 15 ±21.5° Φ 71   (50 × 50) 6.5 120 3.2 M85 × 1
f-110T-532 110 132.94 15 ±21.5° Φ 83   (60 × 60) 7.2 120 3.2 M85 × 1
f-170T-532 170 214.66 14 ±21.8° Φ 129  (91 × 91) 11.8 140 3 M85 × 1
f-170T-20-532 170 204.788 20 ±24° Φ 141 (100 × 100) 8.53 164 4 M102 × 1

Product detail pictures:

Wholesale Price China Laser Diode Focusing Lens - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ detail pictures

Wholesale Price China Laser Diode Focusing Lens - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ detail pictures

Wholesale Price China Laser Diode Focusing Lens - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ detail pictures


Related Product Guide:

We will make just about every exertion for being excellent and perfect, and speed up our actions for standing during the rank of worldwide top-grade and high-tech enterprises for Wholesale Price China Laser Diode Focusing Lens - Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm… – JCZ , The product will supply to all over the world, such as: Slovakia, Marseille, Mexico, Really should any of these items be of interest to you, please let us know. We will be pleased to give you a quotation upon receipt of one's detailed specifications. We've our personal specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
  • The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Mario from Bahrain - 2017.08.28 16:02
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By trameka milhouse from Uruguay - 2018.12.14 15:26